DISPLAY SYSTEM FOR PEON

 

      The system consists of display panel with red, green , yellow and blue round led indicators using superbright leds. The panel has a wireless receiver which receives coded signal from a 4 different wireless rf remotes with the Managers. The display panel will be installed near the waiting position of the peon. Normally all the indicators will be off and only the power on indicator will glow. The remotes will be with the Managers. When a button on remote 1 is pressed the red light the panel will glow and musical buzzer will sound for 5 seconds. After 5 seconds the buzzer will be off but the light will glow. Similarly when buttons on the 2nd , 3rd and 4th remote are pressed green ,yellow and blue lights will glow and buzzer will sound .When the peon attends the call he will press the reset switch on the panel so that the lamps will be off. The system operates within 200 ' distance. Sometimes in RCC structures stardard range is not achieved.
Red light will indicate :-" Call from Manager 1"
Green light will indicate :-" Call from Manager 2 "
Yellow light will indicate :-"Call from Manager 3"
Blue light will indicate :-" Call from Manager 4 ".

The system is extremely useful in Banks, Offices etc.